| Time Delay | 
| 2C An extended time delay on engine starting. Adjustable from 0 to 60 min in 1 second steps. Factory set at 5 minutes. | 
|  | 
| Manual Controls for Automatic Transfer Switches | 
| 6C Reset switch for manual retransfer to normal with automatic retransfer in the event of emergency source failure. | 
| 6D Selector switch for automatic/manual retransfer to normal. Automatic bypass if emergency fails. | 
|  | 
| Engine Generator Controls and Accessories | 
| 12 
Three position engine control selector switch. Positions: 1 - Stop 2 - Automatic 3 - Engine
 | 
| Note: Engine controls containing engine stop positions should be located at the engine generator. (Consult ASCO for application assistance). | 
|  | 
| Indicators | 
| 14A/14B  Additional auxiliary contact sets to indicate switch position. Two sets are standard. Specify total number of sets if more are required. | 
| 18B  Two-pole, double-throw contacts operate when emergency source voltage is present at transfer switch terminals. | 
| 18G  
Two-pole, double-throw contacts operate when normal 
source voltage is present at transfer switch 
terminals | 
| 99  Push-to-Test 
feature on all pilot light indicators | 
|  | 
| Customer Control Circuits | 
| 30A Load-shedding circuit initiated by opening of a customer-supplied contact. | 
| 30B Load-shedding circuit initiated by removal of customer-supplied control voltage. (Specify voltage). | 
| 31Z Selective load disconnect control contacts (two provided) which operate with time delay prior to and/or after load transfer and retransfer. | 
| 43R   
Terminal block for all customer control connections 
on 30-150 amp only (standard on all other sizes). | 
|  | 
| Neutral Conductor Options | 
| Solid neutral, with fully-rated terminals. (AL-CU) UL Listed. | 
| Conventional neutral switching pole. | 
| Overlapping neutral transfer contacts. Allows for proper ground-fault sensing and avoids generator voltage transients during transfer. | 
| Specify 
neutral option in catalog number, see page 16 for 
instructions | 
|  | 
| Extension Harness | 
| 37B 
Six foot (6') extension harness to increase distance 
between transfer switch and control panel on 
open-type units | 
|  | 
| Analog Load Metering Options | 
| 23B Three phase ammeter with selector switch (with current transformers and shorting blocks). | 
| 24B 
Three phase voltmeter with selector switch | 
| Notes: Refer to ASCO 7000 Series Data Monitor which provides voltage, frequency and power monitoring. | 
|  | 
| Serial Communications | 
| 72A 
Serial communication module for remote 
communications to ASCO Power Quest products | 
|  | 
|  | 
| Surge Protection - ASCO Pulsar 450 rated 40KA | 
| 73AC1 Normal source protection. (3Ø, 4wire WYE) | 
| Emergency source protection. (3Ø, 4wire WYE)73AC2 | 
| Load side protection. (3Ø, 4wire WYE)73AC3 | 
| Other distribution voltages available (Contact ASCO). Notes: | 
|  | 
|  | 
| Bypass Isolation Switch Options | 
| 14A1 Auxiliary contact to close in Bypass to Normal position. | 
| 14B1 Auxiliary contact to close in Bypass to Emergency position. | 
| 14T Auxiliary contact to close when transfer switch is in Automatic position. | 
| 14U Auxiliary contact to close when transfer switch is in Isolate position. | 
| 14V Auxiliary; contact to close when transfer switch is in Test position. | 
|  | 
|  | 
| ATS Bypass Isolation Drawout Features (1000-2000 amperes) | 
| 82B  Transfer switch lifting yoke to facilitate the removal of the transfer switch from the drawout carriage. | 
| 82C Automatic shutters to provide isolation of bus stabs. | 
|  | 
| Notes: An externally operable quick-make, quick-break (QMQB), manual handle is available on some 7000 Series product configurations. (Consult ASCO for guidance). |