| Reliance Controls |
| Reliance Controls Master Product List |
|
 |
 |
 |
 |
 |
 |
 |
| ProTran Indoor |
ProTran Outdoor |
CSR |
TRc |
TCA |
TRB |
|
 |
| Master Product List - Dealer and Electrican Product List |
RC Master (1073) |
| 30 Amp to 200 Amp Utility and Generator. - Service entrance, main panel or sub-panel. bus. - 6 to 36 branch circuit breakers. |
Category: Transfer Switches Status: New |
|
|
|
|
| |
Power Inlet Boxes |
 GeneratorJoe! |
 |
 |
 |
|
Click on pictures for larger view. |
| Model Number |
PB15 |
PB20 |
PB30 |
PB31 |
PB33 |
PB50 |
PB51 |
| Max. Input Amps |
15 |
20 |
30 |
30 |
30 |
50 |
50 |
| For Use With Models |
15114 |
All
20A, 250V Models |
All
30A, 250V Models |
30114A |
All
30A, 250V Models |
All
50A, 250V Models |
All
50A, 250V Models |
| Rating/Configuration |
15A@125V
5-15 |
20A@250V
L14-20 |
30A@250V
L14-30 |
30A@125V
L5-30 |
30A@3ØY/208V
L21-30 |
50A@125VAC |
50A@250VAC |
| Inlet |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Circuit Breaker |
No |
No |
No |
No |
No |
No |
No |
| Max. Gen. Input kW |
1.875 |
5 |
7.5 |
3.75 |
10.8 |
6.250 |
12.5 |
|
Connector |
5-15 |
L14-20 |
L14-30 |
L5-30 |
LI21-30 3 Phase |
CS6365 |
CS6360 |
| Dimensions, inches |
6" H x 4" W x 2 5/8" D |
| Weight, lbs |
2.5 |
Raintight NEMA 3R Power Inlet Boxes are designed for use with Pro/Tran transfer switches, Panel/Link manual transfer panels and generator-ready load centers. The power inlet box may be installed indoors or outdoors, in the area where the generator is being used. Using one of the four combination 1/2 inch and 3/4 inch knockouts (one on each side, bottom and back), the power inlet box can be wired directly to the transfer switch or panel. The exclusive patented design provides generous wiring space and facilitates rough-in. If you require a circuit breaker at the inlet box, use the PR Series inlet box that includes a circuit breaker. Select a box
that matches the maximum amperage of the transfer switch. |
|
PR Power Inlet Boxes |
 |
 NEMA Type 3R Enclosure |
| Model Number |
PR20 |
PR30 |
PR50 |
| Description |
Power Inlet Panel |
Power Inlet Panel |
Power Inlet Panel |
| Max. Input Amps |
20 |
30 |
50 |
| For Use With Models |
All 20A, 250V Models |
All 30A, 250V Models |
All 50A, 250V Models |
| Rating/Configuration |
20A@250V,
L14-20 |
30A@250V,
L14-30 |
50A@250V,
C56365 |
| Inlet |
Yes |
Yes |
Yes |
| Circuit Breaker Included |
Yes |
Yes |
Yes |
| Max. Gen. Input kW |
5 |
7.5 |
12.5 |
|
Connector |
L14-20 |
L14-30 |
CS6365 |
| Dimensions, inches |
9" H x 6" W x 5" D |
| Weight, lbs |
1 |
|
The PR Series Power Inlet Boxes includes a circuit breaker. Select a box that matches the maximum amperage of the transfer switch. Raintight NEMA 3R power inlet box designed for use with the Pro/Tran transfer switches and Panel/Link manual transfer panels and generator-ready load centers. The power inlet box may be installed indoors or outdoors, in the area where the generator is being used. Using one of the four combination 1/2 inch and 3/4 inch knockouts (one on each side, bottom and back), the power inlet box can be wired directly to the transfer switch or panel. The exclusive patented design provides generous wiring space and facilitates
rough-in. |
|
Power Inlet Kits - for use with Panel/Link® |
Nobody gets the job done like GeneratorJoe! |

|
| Model Number |
PK20 |
PK30 |
PK50 |
| Max. Input Amps |
20 |
30 |
50 |
| For Use With Models |
TRC, TRR, TTH, TTT, TTV & TWB |
TRC, TRR, TTH, TTT, TTV & TWB |
TRC, TRR, TTH, TTT, TTV & TWB |
| Rating/Configuration |
20A@250V
L14-20 |
30A@250V
L14-30 |
50A@250V
C56365 |
| Circuit Breaker Included |
No |
No |
No |
| Max. Gen. Input kW |
5 |
7.5 |
12.5 |
| Dimensions, inches |
3" H x 3" W x 3" D |
| Weight, lbs |
1 |
Suitable for installation into a 2 1/2" knockout on any indoor or outdoor Panel/Link transfer panel or lead center, TRC series and larger. UL listed. |
| |
Power Cords |
Nobody gets the job done like GeneratorJoe! |

|
| Model Number |
PC2010 |
PC2020 |
PC2040 |
PC3010 |
PC3020 |
PC3040 |
PC5010 |
PC5020 |
PC5040 |
| Length Ft. |
10 |
20 |
40 |
10 |
20 |
40 |
10 |
20 |
40 |
| Amps |
20 |
20 |
20 |
30 |
30 |
30 |
50 |
50 |
50 |
| Voltage |
125/250VAC |
125/250VAC |
125/250VAC |
125/250VAC |
125/250VAC |
125/250VAC |
125/250VAC |
125/250VAC |
125/250VAC |
| NEMA Configuration |
L14-20 |
L14-20 |
L14-20 |
L14-30 |
L14-30 |
L14-30 |
CS6364 |
CS6364 |
CS6364 |
| Shipping Weight, lbs |
3.5 |
5 |
7.5 |
3.5 |
5 |
12 |
9 |
15 |
21 |
| Max. Gen. Input kW |
5 |
5 |
5 |
7.5 |
7.5 |
7.5 |
12.5 |
12.5 |
12.5 |
| These heavy duty cord sets are designed for use with Reliance manual transfer switches, transfer panels and power inlet boxes. UL Listed. Three lengths to choose from. |
|
Watt Meter Boxes |
 GeneratorJoe! |
 |
|
Click on pictures for larger view. |
| Model Number |
MB75 |
MB125 |
| Components Included/Rating |
(2) Watt Meters
3.75 kW each |
(2) Watt Meters
6.25 kW each |
| For Use With Models |
Panel/Link® |
Panel/Link® |
| Shipping Weight, lbs |
2.5 |
7.5 |
| Max. Gen. Input kW |
2.5 |
12.5 |
| The Reliance wattmeter boxes are ideal for use with any 125/250VAC installation where balancing the generator load is necessary for optimum performance. UL listed. |
|
| |
|
| Load-Side Transfer Switches | Manual Transfer Switches | Main Breaker Transfer Panels | T/Power Transfer Accessories | |
| Installation Diagrams | Installation Video | General Installation Instructions | Buss Details | |
| Knockout Patterns | Gen-Tran Model Conversion | About Transfer Switches | Transfer Switch Information | |
| FAQ - About Transfer Switches | FAQ Pro/Tran Transfer Switches | Generator Safety | GeneratorSafety Video | |
| Proper Generator Operation | Basic Plug & Receptacle Guide | Six Reasons to Buy |
| |
 |
 |
 |
| TRR |
TTH |
|
 |
|
|
Call us for information or to order at 707 539-9003 (8 A.M. to 6 P.M. California, Pacific Time) or write sales@generatorjoe.net.
Notice: Specifications, features, controls and other data subject to change, substitution or modification without notice. Some data may be approximate. We recommend that you review the Product Details, Product Brochures and Warranty for this product. Manufacturers may require professional startup services to validate warranties. All equipment should be sized, installed, started and maintained by professionals or knowledgeable users. Sales of equipment subject to conditions of sale posted on the website at Policy & Warranties, subject to change without notice.
*If this product has downloadable files, you may need Adobe Acrobat Reader installed on your computer to open the files. If you do not have this software, you may download it free from Adobe at Get Adobe Reader
|
|
|
|