




|
 |
|
|
| GE Zenith |
| ZTS-BOT, ZTS-BDT, ZTS-BCT, ZTS-BOT-O, ZTS-BDT-O & ZTS-BCT-O |
|
 |
 |
 |
 |
 |
| Door Opened |
Door Closed |
MX150 Control Panel |
ZTSM (manual) Door Open |
|
 |
| ZTS-BOT, ZTS-BDT, ZTS-BCT, ZTS-BOT-O, ZTS-BDT-O & ZTS-BCT-O, Industrial Automatic Transfer Switches with Bypass Isolation. Standard, Delayed & Closed Transition, Enclosed & Open |
ZTS-BOT, ZTS-BDT, ZTS-BCT, ZTS-BOT-O, ZTS-BDT-O & ZTS-BCT-O (3070) |
| 40 to 4,000 Amps, Indoor, Outdoor, (Nema 1, 3R, 4, 4X, 12 & Open) >>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available. |
Category: Transfer Switches Status: New |
|
 |
| Product Packages: The packages below are the most common purchases. Includes only the options listed. If you need other options, use the drop down windows to configure your made to order package. |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
| | Standard Features |
| ZTS-BOT, ZTS-BDT, ZTS-BCT, ZTS-BOT-O, ZTS-BDT-O & ZTS-BCT-O, Industrial Automatic Transfer Switches with Bypass Isolation. Standard, Delayed & Closed Transition, Enclosed & Open |
| Available in ZTS (utility-generator), ZTSU (utility-utility), ZTSG (generator-generator) and ZTSM (manual) configurations | Close differential 3 phase under-voltage sensing of Source1 (normal) - factory standard setting 90% pickup, 80% dropout (adjustable); under-frequency sensing of Source 1 factory setting 95% pickup (adjustable). | Contact transfer speed less than 100 milliseconds |
| eTemperature rise test per UL 1008 conducted after overload and endurance tests in unventilated enclosure-exceeds UL requirements | High close-in and withstand capability | NEMA Type 1 enclosure is standard. Also available in NEMA 3R, 4, 4X & 12. |
| Voltage and frequency sensing of the Source 2 (emergency) - factory standard setting 90% pickup voltage, 95% pickup frequency (adjustable). | Indicating LEDs for source availability and switch position. | Pushbuttons for test, exerciser set, timer bypass and program cancel. |
| Special status annunciation of in-phase transfer and timer operation. | Selectable 7, 14, 21 or 28 day (factory set 28 dsays) generator (source2) with or without load exerciser timer. | Diagnostic LED indications in logical one-line configuration. |
| Close differential under-voltage sensing of the normal source. | Voltage and frequency sensing of the emergency source. | Test switch (fast test/load/no load) to simulate normal source failure - automatically bypassed should the emergency source fail . |
| Double throw, interlocked operation . | Electrically operated, mechanically held by a simple, over-center mechanism. | Segmented silver tungsten alloy contacts with separate arcing contacts on 600 amps and above. |
| Arc quenching grids, enclosed arc chambers and wide contact air gap for superior source-to-source isolation on all units. | Control circuit disconnect plug and drive inhibit switch for safe maintenance. | Components accessible for inspection and maintenance without removal of the switch or the power conductors. |
| Mechanical indicator and contact chamber cover designed for inspection, safety and position designation. | | |
|
|
|
| ZTSCT Brochure | Startup Procedures | Preventive Maintainance | MX150 Control Panel | |
| MX250 Control Panel | TVSS Option | View Point Option | ZNET | |
| Battery Charger | Extended Service Plans | NEMA Enclosure Guide |
| |
|
|
Call us for information or to order at 707 539-9003 (8 A.M. to 6 P.M. California, Pacific Time) or write sales@generatorjoe.net.
Notice: Specifications, features, controls and other data subject to change, substitution or modification without notice. Some data may be approximate. We recommend that you review the Product Details, Product Brochures and Warranty for this product. Manufacturers may require professional startup services to validate warranties. All equipment should be sized, installed, started and maintained by professionals or knowledgeable users. Sales of equipment subject to conditions of sale posted on the website at Policy & Warranties, subject to change without notice.
*If this product has downloadable files, you may need Adobe Acrobat Reader installed on your computer to open the files. If you do not have this software, you may download it free from Adobe at Get Adobe Reader
|
|
|
|