ASCO Transfer Switch Group
- Automatic & Manual Transfer
Switches - Enclosed - Series 165 - Standard, Service Entrance and Load Center
As the world leader in emergency and standby power transfer solutions, ASCO
keeps your power on. ASCO, Automatic Transfer Switches and Power Systems
safeguard homes and businesses. ASCO's extensive line of transfer switches is
used to support data and telecommunications networks, industrial processes and
critical installations from health care facilities to financial transaction
centers.
Over the
past 70 years, ASCO has pioneered every major product innovation in power
transfer technology. And ASCO is committed to providing a full range of
quality-driven products, backed by 24-hour nationwide service support.
165 Series, automatic and manual,
100, 200 and
230 amps, indoor or outdoor. -
165P Series, automatic,
125 amps only,
12 or 20 circuits, indoor or outdoor.
165L Series, automatic and manual, 200
amp 30 circuit only, indoor or outdoor. - 165SE Series, automatic and manual,
200 and 225
amps, indoor or outdoor.
All 165
series switches are delivered in a compact design with 2 pole configuration only.
Available in 120/240 VAC only. UL 1008 listed to 240 VAC for total system loads.
True double-throw, inherently interlocked construction,
to absolutely
prohibit connecting both sources together.
- Standard
models in stock, dropped shipped to your location.
FREE SHIPPING when purchased with a generator!
- Available
in Type 1 and 3R enclosures.
-
NEMA 1 size 14.25" W X 24"H X 8" D, 67 lbs-
NEMA 3R size 14.75" X W 25" H X 8.5" D, 82 lbs
- Fixed time
delays helps make these switches economical. If you require changeable time
delays use Series 300, see below.
- Cover is
mounted with four screws and has "keyhole" slide up and off design.
- Automatic
units are mechanically held, electrically operated utilizing a reliable,
field-proven single solenoid operator.
- Manual
units are mechanically held, manually operated,
which is achieved through direct manual quick-make/quick-break handle
from the outside of the enclosure.
- Manual
models are identical to automatic models except that operation is manually
initiated. Ideal for those
applications that have manual start generators without provisions for automatic
engine start.
- Manual
units have pad locking provisions on operating handle to prevent unauthorized
operation.
- Automatic
and manual units feature contacts that are easily accessible for easy inspection
and preventive maintenance. Rated for standby applications and intended for use
only in optional (non-critical) standby systems in accordance with the National
Electrical Code. NEC/NFPA 70, Article 702. Note: Not intended for emergency or
life-support systems.
- Qualified
and listed to CSA C22.2 No. 178 and UL 1008 automatic transfer equipment
standards.
- For
technical data, dimensions, features, remote controls, monitoring, warranty and
other information. See Additional Information below.
- Other
automatic switches available in "Enclosed" versions, Series 300 in larger sizes
and with customer installable options. See
ASCO Transfer Switch Group - Automatic Transfer Switches -
Enclosed - Series 300
-
Other automatic switches available in "Open" versions, Series 300 for use
in equipment rack systems, UL approved. See
ASCO Transfer Switch Group - Automatic Transfer Switches - Open - Series 300
|
Sequence of Operation |
|
See "Sequence of Operation" under Additional Information for details. |
|
When utility power fails for just 3 seconds or more, the Series 165 Automatic
Transfer Switch signals the generator to start. |
|
In less than 30 seconds your electrical power is restored and life returns to
normal. |
|
Once the Series 165 Automatic Transfer Switch senses utility power has reached
an acceptable voltage level for a period of time, it automatically reconnects
your home or business to commercial power. |
|
It then
smoothly shuts the generator down after a one minute cool down period to extend
generator life. |
|
The Series 165 Automatic Transfer Switch automatically performs a test to
simulate utility power failure every 14 days. |
|
The user-friendly control panel also allows you to manually run a test at the
push of a button. |
|
LED indicators let you know the availability of both power sources and transfer
switch positions. |
|
ASCO
165 AUTOMATIC TRANSFER SWITCH
FEATURES AND SPECIFICATIONS |
|
Nominal voltage 120/240 V 60 Hz, single phase.. |
Source
available lights |
|
Meets
National Electrical Code (NEC) and National Fire Protection Association
(NFPA) requirements. |
Listed
to UL1008 for total system loads (motors and all other electrical
loads).
|
|
Convenient terminals to connect neutral and ground conductors from
service and load feeders. |
True
double-throw contacts (no intentional off position), with inherent
mechanical interlocking to prevent connection of generator and utility
source. |
|
Bonding jumper on Neutral and Ground.
|
Simulates a power failure every 14 days to exercise and test your
generator. |
|
3-second time delay to override momentary utility source failures.
|
5-minute time delay on retransfer, to allow utility source to stabilize
prior to transferring the load back to utility.
|
|
15-second transfer to emergency time delay to allow the generator to
stabilize after starting |
1-minute unloaded running time delay for generator cool-down before
shutdown.
|
|
15-second time delay after transfer to the standby source, to ignore
momentary voltage dips on the generator during initial loading.
|
Available in Type 1 (indoor) and Type 3R (outdoor)
enclosures.
|
|
Manually-operated Series 165 Transfer Switches are also available. |
NEMA 1 and 3R size
14.25" W, 24" H, 8" D, 67 lbs -
NEMA 3R size 14.75" X W 25" H X 8.5" D, 82 lbs
|
|
ASCO
165L AUTOMATIC TRANSFER SWITCH, SERVICE ENTRANCE RATED
ADDITIONAL
FEATURES AND SPECIFICATIONS, (includes features of 165 Series) |
|
Listed to
UL 67 Standard for
Switchboards, and meets all NEC requirements for service entrance
equipment. |
Circuit Breaker disconnect on the normal source for
isolation of transfer switch and other electrical equipment.
|
|
Space saving modular design
provides easy access and one-source service responsibility |
Square D Utility and
Generator Breakers |
|
Test switch with time delay
override option |
NEMA 1 size 16" W, 36" H, 6" D, 110 lbs
|
|
Pre - wired and factory tested for easy installation |
NEMA 3R size 16.47" W, 38.13"H, 8.5" D, 122 lbs
|
|
Square D QO Panelboard
with 30 spaces for circuits |
|
|
ASCO
165P AUTOMATIC TRANSFER SWITCH, LOAD CENTER
ADDITIONAL
FEATURES AND SPECIFICATIONS, (includes features of 165 Series) |
|
Listed to
UL
67, 1008and 1449
Standard for
Switchboards, and meets all NEC requirements for service entrance
equipment.. |
Circuit Breaker disconnect on the normal source for
isolation of transfer switch and other electrical equipment.
|
|
Test switch with time delay
override option |
Square D Utility and
Generator Breakers |
|
Pre - wired and factory tested for easy installation |
NEMA 1 size 16" W, 36" H, 6" D, 110 lbs
|
|
Square D QO Panelboard
with 20 spaces for circuits |
NEMA 3R size 16.47" W, 38.13"H, 8.5" D, 122 lbs
|
|