The Baldor Model IDLC100-JU is a IDLC Series generator with 100 kW (125 kVA) 60 Hz, of maximum output. These industrial generators are suitable for prime power and standby use. When you need the dependability of an industrial grade generator, with all the features you need, the IDLC Series is for you. Available in several models, these models are competitively priced to deliver the performance and value found only on more expensive competitors models.
Baldor generators are designed for many applications where power is needed. Baldor generators are manufactured to commercial specifications using the latest manufacturing technologies. All models are built with the quality and reliability you would expect from a leading generator manufacturer. The Barber-Colman brushless alternator used on this model is manufactured to exacting specifications using the latest mass production methods. Baldor generators use technology to control the voltage with a voltage variation less than 3% throughout the entire power range. That means you can use this generator with computers and sensitive electronics, safely, with no sacrifice in performance. This model features a premium Volvo model TAD1241, 4 cylinder, 165 HP, diesel fueled, liquid cooled engine with electric start. This model runs at 1800 RPM and generates 100 kW (125 kVA) 60 Hz,of Standby (emergency or maximum) power and 90 kW prime (continuous) power at a primary voltage of 120/208 VAC, three phase, 60 Hertz, with 1.5% voltage accuracy. Single phase models are available as 120/240 VAC. Three phase models are available as 120/240, 120/208 or 277/480 VAC. If 50 Hz models are available they would be built as a special order. For 50 Hz voltage and amperage ratings, click on the Open Specification Window and then check the 50 Hz check box.
This model comes with a Digital 300 control panel with autostart. If you require voltage and amperage readouts, upgrade to the Digital 400 panel.
This model has economical fuel use of 4 gallons at 1/2 load. Running time is over 25 hours on a typical tank. See Fuel Tanks below.
The price includes a factory warranty of 12 months or 3000 hours whichever comes first.
Open dimensions are 108" Long X 43" Wide X 56" High. Open weight is 2045 lbs. Open quietness is 73 db at 7 meters. Trailers: Many industrial generators may be mounted on trailers. If trailers are available as a option they will be shown in the Trailer Option Window. Rental type generators equipped with single and three phase power are generally supplied with trailers as standard equipment. Enclosures: Weather and sound proof enclosures (if available), are built using steel panels and locking doors on a modular structural base frame. Sound enclosures include a rock-wool layer of insulation, which complies with the prevailing regulations and accomplishes the sound attenuating elements. Most enclosures include hot ambient air extraction fan. Select an enclosure from the Product Options windows, if available. For additional enclosure information click on Enclosure Details in the Additional Information area below. Fuel Tanks: Single walled (non UL) and double walled (UL) tanks are available for this model as shown in Product Options. When base tanks are added, the day tank (if installed) is removed. Tank prices include installation, fuel level gage and fuel line piping, to make a complete operable unit. You may check the running time on that tank size, by viewing the tank in the opened Specification Window or by typing in the gallons or your external tank in the box provided and clicking the arrow. Local codes on fuel tanks vary, check with your local building department and state air quality department to determine any fuel tank requirements for your area. Select the tank you need from the Product Options windows, if available. Select a tank and click "Details" for to see dimensions and other information about that tank. If you have special requirements call your GeneratorJoe sales representative. Transfer Switches: The automatic transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the transfer switch control starts the generator set, checks the generator speed and voltage output and transfers the load to the generator set. When utility power is restored the transfer switch automatically transfers back to utility power. The generator is allowed to cool down for a short period and then shuts down. The system instantly resets itself and is ready for the next power interruption. No action is required by the user. You must select a transfer switch that is the same size in amps (or larger) then your building service or sub-panel. The transfer switch must also be the same size in amps (or larger) than the maximum output of the generator you select. Example: If you have a 12 kW generator operating at 120 VAC single phase, (100 Amps) and a 200 amp building service you need a 200 Amp transfer switch or you must install a 100 Amp sub-panel. Transfer switches should be installed by a licensed electrician. For more information on transfer switches please see About Transfer Switches. Select a transfer switch to go with your generator from the drop down option list at the top of this page under Product Options. The transfer switches shown are compatible with this generator. If you need additional transfer switch poles, auxiliary contacts or communications features, ASCO Transfer Switches. For special needs, volume purchases and other questions, call your GeneratorJoe sales representative at 707 539-9003 for assistance. All ASCO switches are shipped FREE when you purchase the switch with a generator. Other Requirements or Options: If you do not find the options you need in the drop down option windows above or if you have other requirements, please call us and tell us what you require. If your needed option is not available we have many other brands that may provide the options you need or we will have a generator custom made if necessary. Please contact us at (707) 539-9003 or write sales@generatorjoe.net.
Please see our extensive educational area on the left side blue column of this screen under the Information sign.
|
Included Equipment: Generator engine and alternator on welded steel frame open skid mount platform, mounted platform flexible fuel lines, oil drain cock, digital/LCD control panel, mechanical governor, residential muffler (enclosed models), residential muffler (open models), spring isolators, 12 volt electric starter air filter, radiator, blower fan and guards, battery tray, battery cables, batteries with electrolyte, owners manual and warranty. Other options are NOT included please purchase the options from the option lists. Units are shipped in shrunk plastic film, on skids.
| IDLC Series, 100 kW (125 kVA) 60 Hz, SKU BAIN-100D306, Model IDLC100-JU, (Open, No Enclosure) | AC Voltmeter | |
| Low Oil Shutdown | Class H insulation | Oil pressure, temperature, over speed and over crank shutdown |
| Meets UL 508 | Meets UL 2200 | Mechanical governor |
| NEMA, IEC, IEEE, CSA & BS standards | EPA/CARB | Meets NFPA 70 & NFPA 110 |
| IDLC Series, 100 kW (125 kVA) 60 Hz, SKU BAIN-100D306, Model IDLC100-JU, (Open, No Enclosure) | ||
| Weather enclosure | Electronic governor | Industrial silencer |
| Critical silencer | Exhaust flex | Exhaust extension |
| Main line circuit breaker | Space heater | Batteries |
| Battery rack, cables and charger | Coolant heater | Sub-base fuel tank |
| Flexible fuel lines | Sound attenuation | Remote communication |
| Trailer mounted | Oil heater | Vibration isolators |
| Bypass oil filter | Rain cap | Panel lights with switch |
| Exciter field circuit breaker | Export crating | |