Baldor, Industrial Generator, 102 kW, (128 kVA) 60 Hz,, LP/NG fueled, liquid cooled, three phase, Model GLC102

pixie PowerPixie™
generatorjoe GeneratorJoe™

Industrial Generator, Baldor, IGLC Series, 102 kW (128 kVA) 60 Hz, SKU BAIN-102T344, Model GLC102, (Open, No Enclosure), GM V6 4.3L, three phase, LP/NG fueled, liquid cooled, 1800 RPM, electric start, EPA/CARB, Baldor Generator

GLC102, BAIN-102T344
GLC102, BAIN-102T344

  Product Packages

IGLC Series, 102 kW (128 kVA) 60 Hz, SKU BAIN-102T344, Model GLC102, Open, No Enclosure   Our Price Qty
GM V6 4.3L, three phase, LP/NG fueled, liquid cooled, 1800 RPM, electric start, EPA/CARB $23,000.78
IGLC Series, 102 kW (128 kVA) 60 Hz, SKU BAIN-102T344, Model GLC102, with Weather Enclosure   Our Price Qty
GM V6 4.3L, three phase, LP/NG fueled, liquid cooled, 1800 RPM, electric start, EPA/CARB $27,257.82
Package Includes: Weather Enclosure, (100-105 kW)  
IGLC Series, 102 kW (128 kVA) 60 Hz, SKU BAIN-102T344, Model GLC102, with Sound Enclosure   Our Price Qty
GM V6 4.3L, three phase, LP/NG fueled, liquid cooled, 1800 RPM, electric start, EPA/CARB $28,854.49
Package Includes: Sound Enclosure, (100-105 kW)  

The Baldor Model GLC102 is a IGLC Series generator with 102 kW (128 kVA) 60 Hz, of maximum output. These industrial generators are suitable for prime power and standby use. When you need the dependability of an industrial grade generator, with all the features you need, the IGLC Series is for you. Available in several models, these models are competitively priced to deliver the performance and value found only on more expensive competitors models.

Baldor generators are designed for many applications where power is needed. Baldor generators are manufactured to commercial specifications using the latest manufacturing technologies. All models are built with the quality and reliability you would expect from a leading generator manufacturer.

The Baldor brushless alternator used on this model is manufactured to exacting specifications using the latest mass production methods. Baldor generators use technology to control the voltage with a voltage variation less than 3% throughout the entire power range. That means you can use this generator with computers and sensitive electronics, safely, with no sacrifice in performance.

This model features a premium GM model V6 4.3L, 8 cylinder, 150 HP, LP/NG fueled, liquid cooled engine with electric start. This model runs at 1800 RPM and generates 102 kW (128 kVA) 60 Hz,of Standby (emergency or maximum) power and 91.8 kW prime (continuous) power at a primary voltage of 120/208 VAC, three phase, 60 Hertz, with 1.5% voltage accuracy. Single phase models are available as 120/240 VAC. Three phase models are available as 120/240, 120/208 or 277/480 VAC. If 50 Hz models are available they would be built as a special order. For 50 Hz voltage and amperage ratings, click on the Open Specification Window and then check the 50 Hz check box.
 
This model comes with a Digital 300 control panel with autostart. If you require voltage and amperage readouts, upgrade to the Digital 400 panel.
 
This model has economical fuel use of 320.35 gallons at 1/2 load. Running time is over 0.3 hours on a typical tank. See Fuel Tanks below.
 
The price includes a factory warranty of 12 months

Open dimensions are 88" Long X 44" Wide X 50" High. Open weight is 3800 lbs. Enclosed dimensions are 88" Long X 44" Wide X 58" High. Enclosed weight is 4200 lbs. Open quietness is 80 db at 7 meters. Enclosed quietness is 73 db at 7 meters.

Enclosures: Weather and sound proof enclosures (if available), are built using steel panels and locking doors on a modular structural base frame. Sound enclosures include a rock-wool layer of insulation, which complies with the prevailing regulations and accomplishes the sound attenuating elements. Most enclosures include hot ambient air extraction fan. Select an enclosure from the Product Options windows, if available. For additional enclosure information click on Enclosure Details in the Additional Information area below.

Transfer Switches: The automatic transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the transfer switch control starts the generator set, checks the generator speed and voltage output and transfers the load to the generator set. When utility power is restored the transfer switch automatically transfers back to utility power. The generator is allowed to cool down for a short period and then shuts down. The system instantly resets itself and is ready for the next power interruption. No action is required by the user.

You must select a transfer switch that is the same size in amps (or larger) then your building service or sub-panel. The transfer switch must also be the same size in amps (or larger) than the maximum output of the generator you select. Example: If you have a 12 kW generator operating at 120 VAC single phase, (100 Amps) and a 200 amp building service you need a 200 Amp transfer switch or you must install a 100 Amp sub-panel. Transfer switches should be installed by a licensed electrician. For more information on transfer switches please see About Transfer Switches.

Select a transfer switch to go with your generator from the drop down option list at the top of this page under Product Options. The transfer switches shown are compatible with this generator. If you need additional transfer switch poles, auxiliary contacts or communications features, ASCO Transfer Switches. For special needs, volume purchases and other questions, call your GeneratorJoe sales representative at 707 539-9003 for assistance. All ASCO switches are shipped FREE when you purchase the switch with a generator.

Other Requirements or Options: If you do not find the options you need in the drop down option windows above or if you have other requirements, please call us and tell us what you require. If your needed option is not available we have many other brands that may provide the options you need or we will have a generator custom made if necessary. Please contact us at (707) 539-9003 or write sales@generatorjoe.net.

CLICK> Open Specification Window on the blue bar immediately above to see detailed specifications on this product. A window will fold down.
In the opened specification window you can find conversions for metric measurements, single phase deration of three phase units, derating calculations for elevation and temperature as well as fuel consumption and total run time by tank size. Click the Open Specification Window button to see these utilities and additional information.
Accessories available for this model are shown in Product Options above. Select an option in the drop down windows and the price will be recalculated automatically.
Additional Information on this product is available on buttons and links at the bottom of this page.
Transfer Switches shown on in Product Options (above) are matched to this generator. For details about transfer switches go to the Additional Information below.

Please see our extensive educational area on the left side blue column of this screen under the Information sign.

Included Equipment:

Generator engine and alternator on welded steel frame, open skid mount platform, spring isolators, analog/digital control panel, (Standard. includes common fail relay kit), emergency stop switch, electronic governor, mail line circuit breaker, residential muffler (enclosed models), none muffler (open models), 12 volt electric starter, not included battery charger, included charging alternator, block heater, air filter, radiator, blower fan and guards, battery tray, battery cables, oil drain cock and extension, owners manual and warranty. Batteries are not included. Other options are NOT included, please purchase the options from the option lists.

Standard Features
IGLC Series, 102 kW (128 kVA) 60 Hz, SKU BAIN-102T344, Model GLC102, (Open, No Enclosure)
12 Volt Starting
Solid State Controls - Full AdjustibilityHeavy Duty Components & Enclosure Suitable for Prime PowerPrototype Tested Per NFPA 110
Electronic GovernorSuper Efficient Brushless Synchronous Four-Pole Alternator Designed to UL 2200 Standards
Industrial Exhaust SilencersMain Line and Field Circuit BreakersShunt Trip
Timers, Controls, Diganostic Indicators, Shutdown Features & Alarms
Options Available
IGLC Series, 102 kW (128 kVA) 60 Hz, SKU BAIN-102T344, Model GLC102, (Open, No Enclosure)
Block HeaterAutomatic Battery ChargerNFPA Remote Control Panel
Alternator HeatersWeather and Sound EnclosuresCSA Certification
Flexible Fuel LinesFuel Strainer fo NG GenSetsAnalog Gauges
Battery HeaterAdditonal Operator and Maintenance Manuals