Broadcrown, Industrial Generator, 11.4 kW, (14 kVA) 60 Hz,, diesel fueled, liquid cooled, three phase, Model BCM 11-60 T2

pixie PowerPixie™
generatorjoe GeneratorJoe™

Industrial Generator, Broadcrown, USA Series, 11.4 kW (14 kVA) 60 Hz, or 9.5 kW (11.7 kVA) 50 Hz. SKU BCIN-011D301, Model BCM 11-60 T2, (Open, No Enclosure), Mitsubishi S3L2-W262SD, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, auto start, Tier 3,, Broadcrown Generator

BCM 11-60 T2, BCIN-011D301
BCM 11-60 T2, BCIN-011D301

  Product Packages

USA Series, 11.4 kW (14 kVA) 60 Hz, or 9.5 kW (11.7 kVA) 50 Hz. SKU BCIN-011D301, Model BCM 11-60 T2, Open, No Enclosure   Our Price Qty
Mitsubishi S3L2-W262SD, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, Tier 3 $7,216.25
USA Series, 11.4 kW (14 kVA) 60 Hz, or 9.5 kW (11.7 kVA) 50 Hz. SKU BCIN-011D301, Model BCM 11-60 T2, Open, No Enclosure   Our Price Qty
Mitsubishi S3L2-W262SD, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, Tier 3 $9,250.00
Package Includes: Sound Enclosure, (11-12 kW)  
USA Series, 11.4 kW (14 kVA) 60 Hz, or 9.5 kW (11.7 kVA) 50 Hz. SKU BCIN-011D301, Model BCM 11-60 T2, Sound Enclosed   Our Price Qty
Mitsubishi S3L2-W262SD, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, Tier 3 $13,074.40
Package Includes: Sound Enclosure, (11-12 kW), Trailer, 5,000 GVWR, 1 Axle, M126  

The Broadcrown Model BCM 11-60 T2 is a USA Series generator with 11.4 kW (14 kVA) 60 Hz, of maximum output. These industrial generators are suitable for standby and prime power use. When you need the dependability of an industrial grade generator, with all the features you need, the USA Series is for you. Available in several models, these models are competitively priced to deliver the performance and value found only on more expensive competitors models.

Broadcrown generators are designed for many applications where power is needed. Broadcrown generators are manufactured to commercial specifications using the latest manufacturing technologies. All models are built with the quality and reliability you would expect from a leading generator manufacturer.

The Newage Stamford brushless alternator used on this model is manufactured to exacting specifications using the latest mass production methods. Broadcrown generators use technology to control the voltage with a voltage variation less than 3% throughout the entire power range. That means you can use this generator with computers and sensitive electronics, safely, with no sacrifice in performance.

This model features a premium Mitsubishi model S3L2-W262SD, 3 cylinder, 19 HP, diesel fueled, liquid cooled engine with electric start. This model runs at 1800 RPM and generates 11.4 kW (14 kVA) 60 Hz, or 9.5 kW (11.7 kVA) 50 Hz. of Standby (emergency or maximum) power and 10.26 kW 8.5 kW prime (continuous) power at a primary voltage of 277/480 VAC, three phase, 60 Hertz, with 1.5% voltage accuracy.   Single phase models are available as 120/240 VAC. Three phase models are available as 120/240, 120/208 or 277/480 VAC. If 50 Hz models are available they would be built as a special order. For 50 Hz voltage and amperage ratings, click on the Open Specification Window and then check the 50 Hz check box.
 
This model has economical fuel use of 0.8 gallons at 1/2 load. Running time is over 125 hours on a typical tank. See Fuel Tanks below.
 
This model comes with a analog (guages) control panel, , Deep Sea 701M. control panel with autostart. See the factory brocjure for details ab options.
 
The price includes a factory warranty of 12 months

Open dimensions are 52" Long X 21" Wide X 50" High. Open weight is 1270 lbs. Enclosed dimensions are 71.3" Long X 37.4" Wide X 46.9" High. Enclosed weight is 1546 lbs. Open quietness is 84 db at 7 meters. Enclosed quietness is 64 db at 7 meters.

Trailers: Many industrial generators may be mounted on trailers. If trailers are available as a option they will be shown in the Trailer Option Window. Rental type generators equipped with single and three phase power are generally supplied with trailers as standard equipment.

Enclosures: Weather and sound proof enclosures (if available), are built using steel panels and locking doors on a modular structural base frame. Sound enclosures include a rock-wool layer of insulation, which complies with the prevailing regulations and accomplishes the sound attenuating elements. Most enclosures include hot ambient air extraction fan. Select an enclosure from the Product Options windows, if available. For additional enclosure information click on Enclosure Details in the Additional Information area below.

Fuel Tanks: Double walled (UL) tanks are available for this model as shown in Product Options. When base tanks are added, the day tank (if installed) is removed. Tank prices include installation, fuel level gage and fuel line piping, to make a complete operable unit. You may check the running time on that tank size, by viewing the tank in the opened Specification Window or by typing in the gallons or your external tank in the box provided and clicking the arrow. Local codes on fuel tanks vary, check with your local building department and state air quality department to determine any fuel tank requirements for your area. Select the tank you need from the Product Options windows, if available. Select a tank and click "Details" for to see dimensions and other information about that tank. If you have special requirements call your GeneratorJoe sales representative.

Transfer Switches: The automatic transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the transfer switch control starts the generator set, checks the generator speed and voltage output and transfers the load to the generator set. When utility power is restored the transfer switch automatically transfers back to utility power. The generator is allowed to cool down for a short period and then shuts down. The system instantly resets itself and is ready for the next power interruption. No action is required by the user.

You must select a transfer switch that is the same size in amps (or larger) then your building service or sub-panel. The transfer switch must also be the same size in amps (or larger) than the maximum output of the generator you select. Example: If you have a 12 kW generator operating at 120 VAC single phase, (100 Amps) and a 200 amp building service you need a 200 Amp transfer switch or you must install a 100 Amp sub-panel. Transfer switches should be installed by a licensed electrician. For more information on transfer switches please see About Transfer Switches.

Select a transfer switch to go with your generator from the drop down option list at the top of this page under Product Options. The transfer switches shown are compatible with this generator. If you need additional transfer switch poles, auxiliary contacts or communications features, ASCO Transfer Switches. For special needs, volume purchases and other questions, call your GeneratorJoe sales representative at 707 539-9003 for assistance. All ASCO switches are shipped FREE when you purchase the switch with a generator.

Other Requirements or Options: If you do not find the options you need in the drop down option windows above or if you have other requirements, please call us and tell us what you require. If your needed option is not available we have many other brands that may provide the options you need or we will have a generator custom made if necessary. Please contact us at (707) 539-9003 or write sales@generatorjoe.net.

CLICK> Open Specification Window on the blue bar immediately above to see detailed specifications on this product. A window will fold down.
In the opened specification window you can find conversions for metric measurements, single phase deration of three phase units, derating calculations for elevation and temperature as well as fuel consumption and total run time by tank size. Click the Open Specification Window button to see these utilities and additional information.
Accessories available for this model are shown in Product Options above. Select an option in the drop down windows and the price will be recalculated automatically.
Additional Information on this product is available on buttons and links at the bottom of this page.
Transfer Switches shown on in Product Options (above) are matched to this generator. For details about transfer switches go to the Additional Information below.

Please see our extensive educational area on the left side blue column of this screen under the Information sign.

Included Equipment: Generator Mitsubishi diesel engine and Newage Stamford BCI 164 D alternator on a steel frame skid base, single wall day fuel tank, main breaker, analog (guages) control panel, Deep Sea 701M. control panel with autostart, automatic shutdowns, emergency stop button, radiator, industrial grade muffler, air filter, oil drain kit, batteries, battery tray, battery hold down and cables, owners manual and warranty. Other options are NOT included please purchase the options from the option lists.

Standard Features
USA Series, 11.4 kW (14 kVA) 60 Hz, or 9.5 kW (11.7 kVA) 50 Hz. SKU BCIN-011D301, Model BCM 11-60 T2, (Open, No Enclosure)
Water CoolingRadiator pressure cap and drain point
Steel skid base with fork lift pocketsAnti vibration mountingBattery charging alternator
Industrial silencerMain line circuit breakerStart control system