Detroit Diesel - MTU, Industrial Generator, 1000 kW, (1250 kVA) 60 Hz,, diesel fueled, liquid cooled, three phase, Model 1000-XC6DT2-3

pixie PowerPixie™
generatorjoe GeneratorJoe™

Industrial Generator, Detroit Diesel - MTU, C Series, 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. SKU DDIN-1000D323, Model 1000-XC6DT2-3, (Open, No Enclosure), Detroit Diesel 16V-2000G84, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, auto start, Tier 2, UL2200, Detroit Diesel - MTU Generator

1000-XC6DT2-3, DDIN-1000D323
1000-XC6DT2-3, DDIN-1000D323

  Product Packages

C Series, 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. SKU DDIN-1000D323, Model 1000-XC6DT2-3, Open, No Enclosure, w/1705 gallon tank   Our Price Qty
Detroit Diesel 16V-2000G84, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, Tier 2 $176,736.05
Package Includes: 1705 Gallon, Dbl Wall, 24 hour  
C Series, 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. SKU DDIN-1000D323, Model 1000-XC6DT2-3, Weather Enclosed, w/1705 gallon tank   Our Price Qty
Detroit Diesel 16V-2000G84, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, Tier 2 $189,489.80
Package Includes: Weather Enclosure, (1000 kW), 1705 Gallon, Dbl Wall, 24 hour  
C Series, 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. SKU DDIN-1000D323, Model 1000-XC6DT2-3, Sound Enclosed, w/1705 gallon tank   Our Price Qty
Detroit Diesel 16V-2000G84, three phase, diesel fueled, liquid cooled, 1800 RPM, electric start, Tier 2 $203,507.30
Package Includes: Sound Enclosure, (1000 kW), 1705 Gallon, Dbl Wall, 24 hour  

The Detroit Diesel - MTU Model 1000-XC6DT2-3 is a C Series generator with 1000 kW (1250 kVA) 60 Hz, of maximum output. These industrial generators are suitable for standby and prime power use. When you need the dependability of an industrial grade generator, with all the features you need, the C Series is for you. Available in several models, these models are competitively priced to deliver the performance and value found only on more expensive competitors models.

Detroit Diesel - MTU generators are designed for many applications where power is needed. Detroit Diesel - MTU generators are manufactured to commercial specifications using the latest manufacturing technologies. All models are built with the quality and reliability you would expect from a leading generator manufacturer.

The MTU brushless alternator used on this model is manufactured to exacting specifications using the latest mass production methods. Detroit Diesel - MTU generators use technology to control the voltage with a voltage variation less than 3% throughout the entire power range. That means you can use this generator with computers and sensitive electronics, safely, with no sacrifice in performance.

This model features a premium Detroit Diesel model 16V-2000G84, 16 cylinder, 1495 HP, diesel fueled, liquid cooled engine with electric start. This model runs at 1800 RPM and generates 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. of Standby (emergency or maximum) power and 900 kW 750 kW prime (continuous) power at a primary voltage of 277/480 VAC, three phase, 60 Hertz, with 0.25% voltage accuracy.   Single phase models are available as 120/240 VAC. Three phase models are available as 120/240, 120/208 or 277/480 VAC. If 50 Hz models are available they would be built as a special order. For 50 Hz voltage and amperage ratings, click on the Open Specification Window and then check the 50 Hz check box.
 
 
This model comes with a Digital control panel with autostart. If you require voltage and amperage readouts, upgrade to the Digital 400 panel.
 
This model has economical fuel use of 36.7 gallons at 1/2 load. Running time is over 2.7 hours on a typical tank. See Fuel Tanks below.
 
 
The price includes a factory warranty of 48 months or 3000 hours whichever comes first.

Open dimensions are 192.8" Long X 68" Wide X 101.6" High. Open weight is 17636 lbs. Enclosed dimensions are 193" Long X 68" Wide X 121" High. Enclosed weight is 19251 lbs. Open quietness is 101.5 db at 7 meters. Enclosed quietness is 93.5 db at 7 meters.

Trailers: Many industrial generators may be mounted on trailers. If trailers are available as a option they will be shown in the Trailer Option Window. Rental type generators equipped with single and three phase power are generally supplied with trailers as standard equipment.

Enclosures: Weather and sound proof enclosures (if available), are built using steel panels and locking doors on a modular structural base frame. Sound enclosures include a rock-wool layer of insulation, which complies with the prevailing regulations and accomplishes the sound attenuating elements. Most enclosures include hot ambient air extraction fan. Select an enclosure from the Product Options windows, if available. For additional enclosure information click on Enclosure Details in the Additional Information area below.

Fuel Tanks: Double walled (UL) tanks are available for this model as shown in Product Options. When base tanks are added, the day tank (if installed) is removed. Tank prices include installation, fuel level gage and fuel line piping, to make a complete operable unit. You may check the running time on that tank size, by viewing the tank in the opened Specification Window or by typing in the gallons or your external tank in the box provided and clicking the arrow. Local codes on fuel tanks vary, check with your local building department and state air quality department to determine any fuel tank requirements for your area. Select the tank you need from the Product Options windows, if available. Select a tank and click "Details" for to see dimensions and other information about that tank. If you have special requirements call your GeneratorJoe sales representative.

Transfer Switches: The automatic transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the transfer switch control starts the generator set, checks the generator speed and voltage output and transfers the load to the generator set. When utility power is restored the transfer switch automatically transfers back to utility power. The generator is allowed to cool down for a short period and then shuts down. The system instantly resets itself and is ready for the next power interruption. No action is required by the user.

You must select a transfer switch that is the same size in amps (or larger) then your building service or sub-panel. The transfer switch must also be the same size in amps (or larger) than the maximum output of the generator you select. Example: If you have a 12 kW generator operating at 120 VAC single phase, (100 Amps) and a 200 amp building service you need a 200 Amp transfer switch or you must install a 100 Amp sub-panel. Transfer switches should be installed by a licensed electrician. For more information on transfer switches please see About Transfer Switches.

Select a transfer switch to go with your generator from the drop down option list at the top of this page under Product Options. The transfer switches shown are compatible with this generator. If you need additional transfer switch poles, auxiliary contacts or communications features, ASCO Transfer Switches. For special needs, volume purchases and other questions, call your GeneratorJoe sales representative at 707 539-9003 for assistance. All ASCO switches are shipped FREE when you purchase the switch with a generator.

Other Requirements or Options: If you do not find the options you need in the drop down option windows above or if you have other requirements, please call us and tell us what you require. If your needed option is not available we have many other brands that may provide the options you need or we will have a generator custom made if necessary. Please contact us at (707) 539-9003 or write sales@generatorjoe.net.

CLICK> Open Specification Window on the blue bar immediately above to see detailed specifications on this product. A window will fold down.
In the opened specification window you can find conversions for metric measurements, single phase deration of three phase units, derating calculations for elevation and temperature as well as fuel consumption and total run time by tank size. Click the Open Specification Window button to see these utilities and additional information.
Accessories available for this model are shown in Product Options above. Select an option in the drop down windows and the price will be recalculated automatically.
Additional Information on this product is available on buttons and links at the bottom of this page.
Transfer Switches shown on in Product Options (above) are matched to this generator. For details about transfer switches go to the Additional Information below.

Please see our extensive educational area on the left side blue column of this screen under the Information sign.

Included Equipment: Generator Detroit Diesel diesel engine and MTU alternator on a steel frame skid base, single wall day fuel tank, main breaker, digital control panel with autostart, automatic shutdowns, emergency stop button, radiator, industrial grade muffler, air filter, oil drain kit, batteries, battery tray, battery hold down and cables, owners manual and warranty. Other options are NOT included please purchase the options from the option lists.

Standard Features
C Series, 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. SKU DDIN-1000D323, Model 1000-XC6DT2-3, (Open, No Enclosure)
Air cleanerOil pumpJacket water pump
Blower fan & fan driveRadiatorElectric starting motor
Governor, electric isochronousCharging alternatorBattery box & cables
Digital control panelWindows based softwareSelf ventilated and drip proof
No load to full load regulationJacket water heaterMainline circuit breaker
UL2200 listedRadiator duct flangeFlexible coupling
Vibration isolation pads2 year/3000 hour warranty
Options Available
C Series, 1000 kW (1250 kVA) 60 Hz, or 833.3 kW (1041.7 kVA) 50 Hz. SKU DDIN-1000D323, Model 1000-XC6DT2-3, (Open, No Enclosure)
Circuit breakerMufflerSub-base fuel tank
Weatherproof enclosureSound attenuationRemote annunciator