In the event of a power interruption simply use a standard grounded cord to connect the transfer switch to the standby power source. Then throw the double-throw switch on the TF from LINE to GEN and you have power to your forced-air furnace or any other 15A or 20A, 120VAC circuit. The light on the face of the TF will illuminate the area around the switch under standby power. The circuit breaker on the TF provides protection only when the switch is in the GEN position.
The TF151W can be connected to a 15A or 20A, 120VAC branch circuit. Power input, in the standby mode, is limited to 15A maximum. The TF201W can be connected to a 20A, 120VAC branch circuit only. Power input, in the standby mode, is limited to 20A maximum.
· Heavy-duty powder-coated steel enclosure.
· Completely pre-wired.
· Flexible aluminum conduit and fittings included.
· Built-in circuit breaker (UL489).
· Multiple knock-outs for more installation options.
· Built-in light illuminates area under standby power.
· Remarkably easy to install and easy to use.
· No need to throw the
· Can be placed anywhere between the branch circuit breaker in the load center and the furnace.
· Completely isolates the utility power from the standby power source.
· Two-year limited warranty.
· Listed by Underwriters Laboratories Inc. to standard UL1008.
· Suitable for use in accordance with article 702 of the National Electrical Code ANSI/NFPA 70.
| Power Inlet Boxes | |||||||
![]() GeneratorJoe! |
![]() |
![]() |
![]() |
||||
| Click on pictures for larger view. | |||||||
| Model Number | PB15 | PB20 | PB30 | PB31 | PB33 | PB50 | PB51 |
| Max. Input Amps | 15 | 20 | 30 | 30 | 30 | 50 | 50 |
| For Use With Models | 15114 | All 20A, 250V Models |
All 30A, 250V Models |
30114A | All 30A, 250V Models |
All 50A, 250V Models |
All 50A, 250V Models |
| Rating/Configuration | 15A@125V 5-15 |
20A@250V L14-20 |
30A@250V L14-30 |
30A@125V L5-30 |
30A@3ØY/208V
L21-30 |
50A@125VAC | 50A@250VAC |
| Inlet | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Circuit Breaker | No | No | No | No | No | No | No |
| Max. Gen. Input kW | 1.875 | 5 | 7.5 | 3.75 | 10.8 | 6.250 | 12.5 |
| Connector | 5-15 | L14-20 | L14-30 | L5-30 | LI21-30 3 Phase | CS6365 | CS6360 |
| Dimensions, inches | 6" H x 4" W x 2 5/8" D | ||||||
| Weight, lbs | 2.5 | ||||||
Raintight NEMA 3R Power Inlet Boxes are designed for use with Pro/Tran transfer switches, Panel/Link manual transfer panels and generator-ready load centers. The power inlet box may be installed indoors or outdoors, in the area where the generator is being used. Using one of the four combination 1/2 inch and 3/4 inch knockouts (one on each side, bottom and back), the power inlet box can be wired directly to the transfer switch or panel. The exclusive patented design provides generous wiring space and facilitates rough-in. If you require a circuit breaker at the inlet box, use the PR Series inlet box that includes a circuit breaker. Select a box that matches the maximum amperage of the transfer switch. |
|||||||
|
Power Inlet Kits - for use with Panel/Link® | ||
Nobody gets the job done like GeneratorJoe! |
|||
| Model Number | PK20 | PK30 | PK50 |
| Max. Input Amps | 20 | 30 | 50 |
| For Use With Models | TRC, TRR, TTH, TTT, TTV & TWB | TRC, TRR, TTH, TTT, TTV & TWB | TRC, TRR, TTH, TTT, TTV & TWB |
| Rating/Configuration | 20A@250V L14-20 | 30A@250V L14-30 | 50A@250V C56365 |
| Circuit Breaker Included | No | No | No |
| Max. Gen. Input kW | 5 | 7.5 | 12.5 |
| Dimensions, inches | 3" H x 3" W x 3" D | ||
| Weight, lbs | 1 | ||
Suitable for installation into a 2 1/2" knockout on any indoor or outdoor Panel/Link transfer panel or lead center, TRC series and larger. UL listed. |
|||
| Power Cords | |||||||||
Nobody gets the job done like GeneratorJoe! |
|||||||||
| Model Number | PC2010 | PC2020 | PC2040 | PC3010 | PC3020 | PC3040 | PC5010 | PC5020 | PC5040 |
| Length Ft. | 10 | 20 | 40 | 10 | 20 | 40 | 10 | 20 | 40 |
| Amps | 20 | 20 | 20 | 30 | 30 | 30 | 50 | 50 | 50 |
| Voltage | 125/250VAC | 125/250VAC | 125/250VAC | 125/250VAC | 125/250VAC | 125/250VAC | 125/250VAC | 125/250VAC | 125/250VAC |
| NEMA Configuration | L14-20 | L14-20 | L14-20 | L14-30 | L14-30 | L14-30 | CS6364 | CS6364 | CS6364 |
| Shipping Weight, lbs | 3.5 | 5 | 7.5 | 3.5 | 5 | 12 | 9 | 15 | 21 |
| Max. Gen. Input kW | 5 | 5 | 5 | 7.5 | 7.5 | 7.5 | 12.5 | 12.5 | 12.5 |
| These heavy duty cord sets are designed for use with Reliance manual transfer switches, transfer panels and power inlet boxes. UL Listed. Three lengths to choose from. | |||||||||