Indoor and outdoor Power Inlet Boxes and Power Inlet Kits. Our inlet boxes are RainTite with gaskets. Power inlet kits are inlet boxes with breakers. All inlet boxes and other painted surfaces feature a rugged power-coated steel construction.
|
Power Inlet
Boxes |

GeneratorJoe!
|
 |
 |
 |
| |
Click on
pictures for larger view. |
|
Model Number |
PB15 |
PB20 |
PB30 |
PB31 |
PB33 |
PB50 |
PB51 |
|
Max. Input Amps |
15 |
20 |
30 |
30 |
30 |
50 |
50 |
|
For Use With Models |
15114 |
All
20A, 250V Models |
All
30A, 250V Models |
30114A |
All
30A, 250V Models |
All
50A, 250V Models |
All
50A, 250V Models |
|
Rating/Configuration |
15A@125V
5-15 |
20A@250V
L14-20 |
30A@250V
L14-30 |
30A@125V
L5-30 |
30A@3ØY/208V
L21-30 |
50A@125VAC |
50A@250VAC |
|
Inlet |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Circuit Breaker |
No |
No |
No |
No |
No |
No |
No |
|
Max. Gen. Input kW |
1.875 |
5 |
7.5 |
3.75 |
10.8 |
6.250 |
12.5 |
|
Connector |
5-15 |
L14-20 |
L14-30 |
L5-30 |
LI21-30 3 Phase |
CS6365 |
CS6360 |
|
Dimensions, inches |
6" H x 4" W x 2 5/8" D |
|
Weight, lbs |
2.5 |
|
Raintite NEMA
3R Power Inlet Boxes are designed for use with Pro/Tran
transfer switches, Panel/Link manual transfer panels and
generator-ready load centers. The power inlet box may be
installed indoors or outdoors, in the area where the
generator is being used. Using one of the four
combination 1/2 inch and 3/4 inch knockouts (one on each
side, bottom and back), the power inlet box can be wired
directly to the transfer switch or panel. The exclusive
patented design provides generous wiring space and
facilitates rough-in. If you require a circuit breaker
at the inlet box, use the PR Series inlet box that
includes a circuit breaker. Select a box that matches
the maximum amperage of the transfer switch. |
|
PR
Power Inlet Boxes |
 |
NEMA Type
3R Enclosure |
|
Model Number |
PR20 |
PR30 |
PR50 |
|
Description |
Power Inlet Panel |
Power Inlet Panel |
Power Inlet Panel |
|
Max. Input Amps |
20 |
30 |
50 |
|
For Use With Models |
All 20A, 250V Models |
All 30A, 250V Models |
All 50A, 250V Models |
|
Rating/Configuration |
20A@250V, L14-20 |
30A@250V, L14-30 |
50A@250V, C56365 |
|
Inlet |
Yes |
Yes |
Yes |
|
Circuit Breaker Included |
Yes |
Yes |
Yes |
|
Max. Gen. Input kW |
5 |
7.5 |
12.5 |
|
Connector |
L14-20 |
L14-30 |
CS6365 |
|
Dimensions, inches |
9" H x 6" W x 5" D |
|
Weight, lbs |
1 |
|
The PR
Series Power Inlet Boxes includes a circuit breaker.
Select a box that matches the maximum amperage of the
transfer switch. Raintite NEMA 3R power inlet box
designed for use with the Pro/Tran transfer switches and
Panel/Link manual transfer panels and generator-ready
load centers. The power inlet box may be installed
indoors or outdoors, in the area where the generator is
being used. Using one of the four combination 1/2 inch
and 3/4 inch knockouts (one on each side, bottom and
back), the power inlet box can be wired directly to the
transfer switch or panel. The exclusive patented design
provides generous wiring space and facilitates rough-in.
|
|
|
Power
Inlet Kits - for use with Panel/Link® |
|
Nobody gets the job done like
GeneratorJoe! |
 |
|
Model Number |
PK20 |
PK30 |
PK50 |
|
Max. Input Amps |
20 |
30 |
50 |
|
For Use With Models |
TRC, TRR, TTH, TTT, TTV & TWB |
TRC, TRR, TTH, TTT, TTV & TWB |
TRC, TRR, TTH, TTT, TTV & TWB |
|
Rating/Configuration |
20A@250V L14-20 |
30A@250V L14-30 |
50A@250V C56365 |
|
Circuit Breaker Included |
No |
No |
No |
|
Max. Gen. Input kW |
5 |
7.5 |
12.5 |
|
Dimensions, inches |
3" H x 3" W x 3" D |
|
Weight, lbs |
1 |
|
Suitable for
installation into a 2 1/2" knockout on any indoor or
outdoor Panel/Link transfer panel or lead center, TRC
series and larger. UL listed. |
|
|
|
|
Watt
Meter Boxes |

GeneratorJoe!
|
 |
| |
Click on
pictures for larger view. |
|
Model Number |
MB75 |
MB125 |
|
Components
Included/Rating |
(2) Watt
Meters 3.75 kW each |
(2) Watt
Meters 6.25 kW each |
|
For Use With
Models |
Panel/Link® |
Panel/Link® |
|
Shipping
Weight, lbs |
2.5 |
7.5 |
|
Max. Gen.
Input kW |
2.5 |
12.5 |
|
The Reliance
wattmeter boxes are ideal for use with any 125/250VAC installation where
balancing the generator load is necessary for optimum performance. UL
listed. |
Plugs and Connectors: We offer a number of plugs and connectors to make your transfer switch or panel installation complete.
| Male Plugs insert into 4-wire receptacle on your generator |
| Female Connectors insert into 4-wire power Inlet box and/or power inlet on your transfer switch or panel. |
Female Receptacles mount on panels to accept a plug
|
Plugs
and Connectors, Wiring Devices |
|

GeneratorJoe!
|
 |
 |
 |
 |
 |
 |
 |
| |
Click on
pictures for larger view. |
|
Model Number |
L1420C |
L1420P |
L1430C |
L1430P |
LL550C |
LL550P |
L1420R |
L1430R |
|
Max. Input
Amps |
Connector |
Plug |
Connector |
Plug |
Connector |
Plug |
Receptacle |
|
For Use With
Models |
20A@250V
L14-20C |
20A@250V
L14-20P |
30A@250V
L14-30C |
30A@250V
L14-30P |
50A@250V
CS6364 |
50A@250V
CS6365 |
20A@250V
L14-20R |
30A@250V
L14-30R |
Inlet
Included/
Rating/Configuration |
20216A,
R20216B & PB20 |
All
20A, 250V Models |
30216A,
R30216B, 30310A, R30310B & PB30 |
All
30A, 250V Models |
Panel/Link® |
Panel/Link® |
All
20A, 250V Models |
All
30A, 250V Model |
|
Max. Gen.
Input kW |
5 |
5 |
7.5 |
7.5 |
12.5 |
12.5 |
5 |
7.5 |
|
All Reliance
plugs, connectors and receptacles are made in the USA and listed by
Underwriters Laboratories Inc. |
|
|