>>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available."> >>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available.">

GE Zenith, Transfer Switches Generator, ,, , Model ZTG, ZTG-DT & ZTG-O

pixie PowerPixie™
generatorjoe GeneratorJoe™

Transfer Switches, GE Zenith, ZTG, ZTG-DT & ZTG-O, Residential, Commercial & Industrial Transfer Switches, Automatic & Manual, Standard & Delayed Transition, Enclosed & Open, 40 to 3,000 amps, Indoor and Outdoor, (Nema 1, 3R, 4, 4X, 12 & Open) >>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available., GE Zenith Generator

ZTG, ZTG-DT & ZTG-O, ZETR-ZTG, ZTGDT & ZTG-O
ZTG, ZTG-DT & ZTG-O, ZETR-ZTG, ZTGDT & ZTG-O

  Product Packages

Automatic, 100 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$1,465.66
Package Includes: ZTG, 100 Amp, 2 Pole, Enclosed,  
Automatic, 100 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$1,465.66
Package Includes: ZTG, 100 Amp, 2 Pole, Enclosed,  
Automatic, 150 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$1,613.80
Package Includes: ZTG, 150 Amp, 2 Pole, Enclosed,  
Automatic, 150 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$1,613.80
Package Includes: ZTG, 150 Amp, 2 Pole, Enclosed,  
Automatic, 200 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$1,875.52
Package Includes: ZTG, 200 Amp, 2 Pole, Enclosed,  
Automatic, 200 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$1,875.52
Package Includes: ZTG, 200 Amp, 2 Pole, Enclosed,  
Automatic, 200 Amp, 3 Pole, Indoor, Nema 1   Our Price Qty
$2,050.35
Package Includes: ZTG, 200 Amp, 3 Pole, Enclosed,  
Automatic, 200 Amp, 3 Pole, Outdoor, Nema 3R   Our Price Qty
$2,050.35
Package Includes: ZTG, 200 Amp, 3 Pole, Enclosed,  
Automatic, 400 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$2,617.25
Package Includes: ZTG, 400 Amp, 2 Pole, Enclosed,  
Automatic, 400 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$2,617.25
Package Includes: ZTG, 400 Amp, 2 Pole, Enclosed,  
Automatic, 400 Amp, 3 Pole, Indoor, Nema 1   Our Price Qty
$3,053.28
Package Includes: ZTG, 400 Amp, 3 Pole, Enclosed,  
Automatic, 400 Amp, 3 Pole, Outdoor, Nema 3R   Our Price Qty
$3,053.28
Package Includes: ZTG, 400 Amp, 3 Pole, Enclosed,  

GE Zenith - ZTG Series Transfer Switches - Commercial & Industrial - Automatic & Manual, Enclosed & Open, Indoor & Outdoor
Zenith is of the world leaders in emergency and standby power transfer solutions, Zenith keeps your power on. Zenith is committed to providing a full range of quality-driven products, backed by nationwide 24-hour service and support.

This series of automatic transfer switches is designed for commercial and industrial standard applications requiring dependability and ease of operation. These switches combine reliability, flexibility and ease of use in a rugged industrial package. ZTG switches work together with any remote-start generator that use two-wire control, allowing the standby power system to be fully automatic. Designed for standard applications, the ZTG Series builds on ZTS technology while providing a pre-engineered project solution.

The MX250 microprocessor control system, includes as standard many of the most common features that are options on competing transfer switches. It also provides an intuitive user interface, communications capability and self diagnostics.

The transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the control starts the generator set and transfers the load to the generator set as soon as the generator reaches speed and voltage. When utility power is restored the transfer switch automatically transfers back to utility power, shutting down the generator and instantly resetting itself for the next power interruption. No action is required by the owner.

We recommend ZTG switches when purchasing any standby or primary power generator systems. If you require optional features such as auxiliary contacts, extra power poles to switch neutral, special enclosures or communications features, we recommend that you purchase this ZTG series. If you require a switch that will handle large motor loads or inductive loads see GE Zenith, ZTS Industrial Automatic Transfer Switches, Service Entrance. For Residential and commercial applications see GE Zenith, ZTX Light Duty Residential & Commercial Transfer Switches. Prices and the most common accessories are online on this website for all models.

  • GE Zenith’s ZTG Series Automatic Transfer Switches are designed for emergency and standby applications.
  • Standard models in stock, dropped shipped to your location. FREE SHIPPING when purchased with a generator!
  • Sizes include 40 to 3,000 amps with 2, 3 or 4 pole configurations.
  • Available 120/240 VAC, 120/208 VAC, 277/480 VAC and other voltages up to 600 VAC. See Factory Brochure under Additional Information.
  • Switch is true double throw, mechanically interlocked and mechanically held, electrically operated utilizing a reliable, field-proven single solenoid operator.
  • Switch mechanism absolutely prohibits connecting both sources together. Cannot be over-ridden.
  • Available in ZTG (standard) or ZTGD (delayed transition) models
  • Available in Utility to Generator, Utility to Utility and Generator to Generator application configurations.
  • Available in NEMA Type 1 (indoor), 3R (outdoor) enclosures and open (back-panel mounted) configurations as well as NEMA 4, 4X & 12.
  • Dimensions shown on ZTG Dimensions under Additional Information.
  • GE Zenith’s ZTX switches are equipped with the MX150 control panel. This microprocessor control includes:
  • Under-voltage sensing (90% pickup, 80% dropout) of Source 1 (normal).
  • Voltage and frequency sensing of Source 2 (emergency), (90% voltage, 95% frequency pickup).
  • Time Delay Engine Start (P) - 0-10 seconds, factory setting 3 seconds.
  • Time Delay Engine Warm-up (W) - Transfer to Emergency (Source 2) - 0 -5 minutes, factory setting 1 second.
  • Time Delay Utility Stabilization/Retransfer to Utility (Source 1) (T) - 0-60 minutes, factory setting 30 minutes.
  • Time Delay Engine Cool Down (U) - 0-60 minutes, factory setting 5 minutes.
  • Generator exerciser timer built-in. 365 day adjustable time setting. Factory set at 7 days. Exercises Source 2 with or without load.
  • Switches feature contacts that are easily accessible for easy inspection and preventive maintenance.
  • Rated for standby applications and intended for use only in optional (non-critical) standby systems in accordance with the National Electrical Code. NEC/NFPA 70, Article 702.
  • Not intended for emergency or life-support systems.
  • Qualified and listed to UL 1008, CSA 22.2 and IEC, 480 VAC 50/60 Hz for automatic transfer equipment standards.
  • For technical data, dimensions, features, remote controls, monitoring, warranty and other information. See Additional Information below.

Sequence of Operation of A Transfer Switch

When utility power fails for just 3 seconds or more, the ZTG switch signals the generator to start.
In less than 30 seconds your electrical power is restored and life returns to normal.
Once the ZTG switch senses utility power has reached an acceptable voltage level for a period of time, it automatically reconnects your home or business to commercial power.
It then smoothly shuts the generator down after a one minute cool down period to extend generator life.
The ZTG switch automatically performs a test to simulate utility power failure every 14 days.
The user-friendly control panel also allows you to manually run a test at the push of a button.
LED indicators let you know the availability of both power sources and transfer switch positions.
 
 

@@INCLUDED_EQUIPMENT@@

Standard Features
ZTG, ZTG-DT & ZTG-O, Residential, Commercial & Industrial Transfer Switches, Automatic & Manual, Standard & Delayed Transition, Enclosed & Open
Close differential 3 phase under-voltage sensing of Source1 (normal) - factory standard setting 90% pickup, 80% dropout (adjustable); under-frequency sensing of Source 1 factory setting 95% pickup (adjustable).NEMA Type 1 enclosure is standard. Also available in NEMA 3R, 4, 4X & 12.Voltage and frequency sensing of the Source 2 (emergency) - factory standard setting 90% pickup voltage, 95% pickup frequency (adjustable).
Indicating LEDs for source availability and switch position.Pushbuttons for test, exerciser set, timer bypass and program cancel.Special status annunciation of in-phase transfer and timer operation.
Diagnostic LED indications in logical one-line configuration.Close differential under-voltage sensing of the normal source.Voltage and frequency sensing of the emergency source.
Test switch (fast test/load/no load) to simulate normal source failure - automatically bypassed should the emergency source fail .Double throw, interlocked operation .Electrically operated, mechanically held by a simple, over-center mechanism.
Segmented silver tungsten alloy contacts with separate arcing contacts on 600 amps and above.Arc quenching grids, enclosed arc chambers and wide contact air gap for superior source-to-source isolation on all units.Control circuit disconnect plug and drive inhibit switch for safe maintenance.
Components accessible for inspection and maintenance without removal of the switch or the power conductors.Mechanical indicator and contact chamber cover designed for inspection, safety and position designation.
Options Available
ZTG, ZTG-DT & ZTG-O, Residential, Commercial & Industrial Transfer Switches, Automatic & Manual, Standard & Delayed Transition, Enclosed & Open
Selectable 7, 14, 21 or 28 day (factory set 28 dsays) generator (source2) with or without load exerciser timer.Auxiliary contacts (1 each) cclosed in Source 1 (normal) and Source 2 (emergency positions.1.5 Amp, 12 or 24 VDC Battery Charger.