>>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available."> >>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available.">

GE Zenith, Transfer Switches Generator, ,, , Model ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O

pixie PowerPixie™
generatorjoe GeneratorJoe™

Transfer Switches, GE Zenith, ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O, Residential, Industrial Transfer Switches, Automatic & Manual, Standard, Delayed & Closed Transition, Enclosed & Open, 40 to 4,000 amps, Indoor and Outdoor, (Nema 1, 3R, 4, 4X, 12 & Open) >>>> Order online or call PowerPixie @ 707 539-9003 to take your order. GSA Pricing Available., GE Zenith Generator

ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O, ZETR-ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O
ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O, ZETR-ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O

  Product Packages

ZTS, Automatic, 100 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$2,107.82
Package Includes: ZTS, 100 Amp, 2 Pole, Enclosed,  
ZTS, Automatic, 100 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$2,292.29
Package Includes: ZTS, 100 Amp, 2 Pole, Enclosed,, Enclosure, ZTS, 40 to 150 Amp, NEMA 3R  
ZTS, Automatic, 150 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$2,471.04
Package Includes: ZTS, 150 Amp, 2 Pole, Enclosed,, Enclosure, ZTS, 40 to 150 Amp, NEMA 3R  
ZTS, Automatic, 150 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$2,471.04
Package Includes: ZTS, 150 Amp, 2 Pole, Enclosed,, Enclosure, ZTS, 40 to 150 Amp, NEMA 3R  
ZTS, Automatic, 225 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$2,775.63
Package Includes: ZTS, 225 Amp, 2 Pole, Enclosed,  
ZTS, Automatic, 225 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$2,960.10
Package Includes: ZTS, 225 Amp, 2 Pole, Enclosed,, Enclosure, ZTS, 225 to 400 Amp, NEMA 3R  
ZTS, Automatic, 225 Amp, 3 Pole, Indoor, Nema 1   Our Price Qty
$3,377.66
Package Includes: ZTS, 225 Amp, 3 Pole, Enclosed,  
ZTS, Automatic, 225 Amp, 3 Pole, Outdoor, Nema 3R   Our Price Qty
$3,562.13
Package Includes: ZTS, 225 Amp, 3 Pole, Enclosed,, Enclosure, ZTS, 225 to 400 Amp, NEMA 3R  
ZTS, Automatic, 400 Amp, 2 Pole, Indoor, Nema 1   Our Price Qty
$4,258.54
Package Includes: ZTS, 400 Amp, 2 Pole, Enclosed,  
ZTS, Automatic, 400 Amp, 2 Pole, Outdoor, Nema 3R   Our Price Qty
$4,877.73
Package Includes: ZTS, 400 Amp, 3 Pole, Enclosed,, Enclosure, ZTS, 225 to 400 Amp, NEMA 3R  
ZTS, Automatic, 400 Amp, 3 Pole, Indoor, Nema 1   Our Price Qty
$4,693.26
Package Includes: ZTS, 400 Amp, 3 Pole, Enclosed,  
ZTS, Automatic, 400 Amp, 3 Pole, Outdoor, Nema 3R   Our Price Qty
$4,877.73
Package Includes: ZTS, 400 Amp, 3 Pole, Enclosed,, Enclosure, ZTS, 225 to 400 Amp, NEMA 3R  

GE Zenith - ZTS Series Transfer Switches - Commercial & Industrial - Automatic & Manual, Enclosed & Open, Indoor & Outdoor
Zenith is of the world leaders in emergency and standby power transfer solutions, Zenith keeps your power on. Zenith is committed to providing a full range of quality-driven products, backed by nationwide 24-hour service and support.

This series of automatic transfer switches is designed for commercial and industrial standard applications requiring dependability and ease of operation. These switches combine reliability, flexibility and ease of use in a rugged industrial package. ZTS switches work together with any remote-start generator that use two-wire control, allowing the standby power system to be fully automatic. Designed for standard applications, the ZTS Series builds on ZTS technology while providing a pre-engineered project solution.

The ZTS Series is the building block of our transfer switch product line. This ruggedly built power contactor family of switches has been specifically designed for transfer switch duty with dependability, versatility and user friendliness of prime concern. ZTS switches are available in NEMA enclosures to the customer’s specifications or open type construction for switchboard installation.

he power panel components, consisting of power switching contacts, drive mechanism and terminal lugs, are mounted on a specially formed panel. Logic devices including microprocessor control auxiliary time delays and special accessory equipment are assembled on the door for ease of maintenance and separation from the power section. The MX250 microprocessor control system, includes as standard many of the most common features that are options on competing transfer switches. It also provides an intuitive user interface, communications capability and self diagnostics.

The transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the control starts the generator set and transfers the load to the generator set as soon as the generator reaches speed and voltage. When utility power is restored the transfer switch automatically transfers back to utility power, shutting down the generator and instantly resetting itself for the next power interruption. No action is required by the owner.

We recommend ZTS switches when purchasing any standby or primary power generator systems. If you require less features or a lower price point then this series, See the ZTG series, See GE Zenith, ZTG & ZTGDT, Residential, Commercial & Industrial Transfer Switches. If you require a switch that will handle large motor loads or inductive loads, See GE Zenith, ZTS Industrial Automatic Transfer Switches, Service Entrance. For Residential and commercial applications, See GE Zenith, ZTX Light Duty Residential & Commercial Transfer Switches. For ZTSCT Closed Transition, ZBTS Automatic Transition Bypass, ZBTSD Delayed Transition Bypass and ZBTSCT Closed Transition Bypass, See GE Zenith, ZTSCT, ZBTS, ZBTSD & ZBTSCT, Industrial Automatic Transfer Switches. Prices and the most common accessories are online on this website for all models.

  • GE Zenith’s ZTS Series Automatic Transfer Switches are designed for emergency and standby applications.
  • Standard models in stock, dropped shipped to your location. FREE SHIPPING when purchased with a generator!
  • Sizes include 40 to 4,000 amps with 2, 3 or 4 pole configurations.
  • Available 120/240 VAC, 120/208 VAC, 277/480 VAC and other voltages up to 600 VAC. See Factory Brochure under Additional Information.
  • Switch is true double throw, mechanically interlocked and mechanically held, electrically operated utilizing a reliable, field-proven single solenoid operator.
  • Switch mechanism absolutely prohibits connecting both sources together. Cannot be over-ridden.
  • Available in ZTS (standard) or ZTSD (delayed transition) models. For other transition models see the link above.
  • Available in Utility to Generator, Utility to Utility and Generator to Generator application configurations.
  • Available in NEMA Type 1 (indoor), 3R (outdoor) enclosures and open (back-panel mounted) configurations as well as NEMA 4, 4X & 12.
  • Dimensions shown on ZTS Dimensions under Additional Information.
  • GE Zenith’s ZTX switches are equipped with the MX250 control panel. This microprocessor control includes:
  • Under-voltage sensing (90% pickup, 80% dropout) of Source 1 (normal).
  • Voltage and frequency sensing of Source 2 (emergency), (90% voltage, 95% frequency pickup).
  • Time Delay Engine Start (P) - 0-10 seconds, factory setting 3 seconds.
  • Time Delay Engine Warm-up (W) - Transfer to Emergency (Source 2) - 0 -5 minutes, factory setting 1 second.
  • Time Delay Utility Stabilization/Retransfer to Utility (Source 1) (T) - 0-60 minutes, factory setting 30 minutes.
  • Time Delay Engine Cool Down (U) - 0-60 minutes, factory setting 5 minutes.
  • Generator exerciser timer built-in. 365 day adjustable time setting. Factory set at 7 days. Exercises Source 2 with or without load.
  • Switches feature contacts that are easily accessible for easy inspection and preventive maintenance.
  • Rated for standby applications and intended for use only in optional (non-critical) standby systems in accordance with the National Electrical Code. NEC/NFPA 70, Article 702.
  • Not intended for emergency or life-support systems.
  • Qualified and listed to UL 1008, CSA 22.2 and IEC, 480 VAC 50/60 Hz for automatic transfer equipment standards.
  • For technical data, dimensions, features, remote controls, monitoring, warranty and other information. See Additional Information below.

Sequence of Operation of A Transfer Switch

When Source 1 voltage fails or drops to a predetermined point (usually 80% of nominal), if required, a circuit is closed to start the engine generator set.

 

When Source 2 reaches 90% of rated voltage and 95% of rated frequency, the drive solenoid is energized through the Source 2 coil control relay, causing the main contacts to disconnect the load from Source 1 and connect it to Source 2.
After the drive solenoid has completed its electrical stroke and is seated, the Source 2 coil control relay opens to disconnect it.
The transfer switch is now mechanically locked in the Source 2 position.
When Source 1 voltage is restored to a predetermined point (usually 90% of nominal), the control voltage sensing energizes.
The Source 1 side coil relay closes, and after the drive solenoid has completed its electrical stroke and is seated, the coil control relay opens to disconnect it.
The transfer switch is now mechanically locked in the Source 1 position.
It then smoothly shuts the generator down after a one minute cool down period to extend generator life.
The ZTS switch automatically performs a test to simulate utility power failure every 14 days.
The user-friendly control panel also allows you to manually run a test at the push of a button.
LED indicators let you know the availability of both power sources and transfer switch positions.

@@INCLUDED_EQUIPMENT@@

Standard Features
ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O, Residential, Industrial Transfer Switches, Automatic & Manual, Standard, Delayed & Closed Transition, Enclosed & Open
Available in ZTS (utility-generator), ZTSU (utility-utility), ZTSG (generator-generator) and ZTSM (manual) configurationsClose differential 3 phase under-voltage sensing of Source1 (normal) - factory standard setting 90% pickup, 80% dropout (adjustable); under-frequency sensing of Source 1 factory setting 95% pickup (adjustable).Contact transfer speed less than 100 milliseconds
eTemperature rise test per UL 1008 conducted after overload and endurance tests in unventilated enclosure-exceeds UL requirementsHigh close-in and withstand capabilityNEMA Type 1 enclosure is standard. Also available in NEMA 3R, 4, 4X & 12.
Voltage and frequency sensing of the Source 2 (emergency) - factory standard setting 90% pickup voltage, 95% pickup frequency (adjustable).Indicating LEDs for source availability and switch position.Pushbuttons for test, exerciser set, timer bypass and program cancel.
Special status annunciation of in-phase transfer and timer operation.Diagnostic LED indications in logical one-line configuration.Close differential under-voltage sensing of the normal source.
Voltage and frequency sensing of the emergency source.Test switch (fast test/load/no load) to simulate normal source failure - automatically bypassed should the emergency source fail .Double throw, interlocked operation .
Electrically operated, mechanically held by a simple, over-center mechanism.Segmented silver tungsten alloy contacts with separate arcing contacts on 600 amps and above.Arc quenching grids, enclosed arc chambers and wide contact air gap for superior source-to-source isolation on all units.
Control circuit disconnect plug and drive inhibit switch for safe maintenance.Components accessible for inspection and maintenance without removal of the switch or the power conductors.Mechanical indicator and contact chamber cover designed for inspection, safety and position designation.
Options Available
ZTS, ZTS-DT, ZTS-CT, ZTS-O, ZTS-DT-O & ZTS-CT-O, Residential, Industrial Transfer Switches, Automatic & Manual, Standard, Delayed & Closed Transition, Enclosed & Open
1.5 Amp, 12 or 24 VDC Battery Charger.