Kubota
GL11000-USA
Plus Options

Instructions and Notes: NOTE: Freight quotes using the freight Quoter are only estimates. Actual freight must be calculated by GeneratorJoe using the closest warehouse, which may be higher or lower, depending on various factors. ASK FOR A FREIGHT QUOTE ON THESE ITEMS.
- Detailed
Description - Priced
Packages - Priced
Options - Detailed
Specifications - Technical
Summary - Model
Features - Lease
Purchase - Product
Families - Product
Finder - Transfer
Switches
-
Detailed DescriptionSKU KUPR-011D102:
Portable SKU KUPR-011D102 The Kubota Model GL11000-USA is a GL Series generator with 11 kW (11 kVA) 60 Hz, of maximum output. These industrial generators are suitable for prime power and standby use. When you need the dependability of an industrial grade generator, with all the features you need, the GL Series is for you. Available in several models, these models are competitively priced to deliver the performance and value found only on more expensive competitors models. Kubota generators are designed for many applications where power is needed. Kubota generators are manufactured to commercial specifications using the latest manufacturing technologies. All models are built with the quality and reliability you would expect from a leading generator manufacturer.
The brush type alternator used on this model is manufactured to exacting specifications using the latest mass production methods. Kubota generators use technology to control the voltage with a voltage variation less than 3% throughout the entire power range. That means you can use this generator with computers and sensitive electronics, safely, with no sacrifice in performance.
This model features a premium Kubota model D722, 3 cylinder, 18.9 HP, diesel fueled, liquid cooled engine with electric start. This model runs at 3600 RPM and generates 11 kW (11 kVA) 60 Hz,of Standby (emergency or maximum) power and 9.9 kW prime (continuous) power at a primary voltage of 120/240 VAC, single phase, 60 Hertz, with voltage accuracy. Single phase models are available as 120/240 VAC. This model has economical fuel use of 0.71 gallons at 1/2 load. Running time is over 10.4 hours on a typical tank. See Fuel Options above.Warranty: The price includes a factory warranty of 12 monthsDimensions: Enclosed dimensions are 50.4" Long X 24.3" Wide X 27.5" High. Enclosed weight is 650 lbs. Enclosed quietness is 68 db at 7 meters.
Features & Highlights - Kubota Diesel Generator GL Series GL11000, Lowboy II Series
Kubota Lowboy II saves space and the environment.
The Lowboy II Series is designed to have the minimum possible height while using the vertical diesel engines. This is achieved by direct coupling of the engine crankshaft with the cooling fan. Since they require less space for operation, the range of possible applications has been greatly increased.
Dependable Generation
Direct Coupled: The generator and the engine are direct-coupled to ensure a more reliable power supply with minimum power loss.A Skewed Rotor & Damper Winding: The wave form distortion is kept to a minimum by the skewed rotor, while the damper winding protects the generator during short circuits and regulates voltage fluctuations during changing loads.
Clean Emissions
The diesel engines selected to power the Lowboy II Series produce far less soot, HC and CO emissions thanks to Kubota's original E-TVCS combustion system. Both Z482 and D722 passed the USA EPA emission Tier 4 regulation.
Ease of Operation
Lower and More Compact: The Lowboy II Series is designed to have the minimum possible height while using vertical diesel engines.
Lower Noise Levels: Four separate improvements help reduced the overall noise levels. First, the large capacity radiator successfully reduces fan related noise by direct coupling its crankshaft with the slower-speed fan. Second, the large capacity, built-in muffler helps reduce exhaust related noise. Third, the longer air cleaner hose reduces air suction related noise. Fourth, the ideally placed inlet vent and its improved design reduce noise coming from the enclosure's opening.Longer Continuous Operation: The Lowboy II Series large capacity (28L/7.4 gal.) fuel tank enables longer continuous operation on a single tank of fuel.
Outstanding Transportability: The special forklift openings on the base of the machine, and the one-point lifting eye enhanced transportability. A remote control kit is also available as an option.
Access Terminals for ATS make Wiring Easy: Access terminals for ATS (automatic transfer switch/not supplied by Kubota) are located behind the control panel. (Requires additional equipment purchase.)Carefree Maintenance
One side maintenance. Oil, fuel, battery and cooling water are all located on one side for easy maintenance
Larger-Capacity Oil Pan: This helps stretching the oil change intervals, thus reducing the overall running costs.
Direct-Coupled: Eliminated the time needed to adjust or replace the cog-belt by direct coupling the generator and the engine.
Double Element Air Cleaners: All LowBoy II generators come with the double element air cleaners as standard equipment. Ideal for heavy duty applications in dusty environments.Increased Safety
Double Circuit Breakers: In addition to the overall circuit protector, each receptacle also has a circuit protector that will shut the engine down to prevent it from overcurrent damages.
Protective Covers: All moving parts of the engine's cooling fan and the generator are covered.
Automatic Shutdown System: This system automatically shuts the engine down when it senses the engine coolant temperature rising excessively or the oil pressure dropping below a safe level.
Start Safety Relay: This relay prevents the starter from engaging again once the engine starts up.Transfer Switches: The automatic transfer switch monitors utility and generator power. When utility power fails or is unsatisfactory, the transfer switch control starts the generator set, checks the generator speed and voltage output and transfers the load to the generator set. When utility power is restored the transfer switch automatically transfers back to utility power. The generator is allowed to cool down for a short period and then shuts down. The system instantly resets itself and is ready for the next power interruption. No action is required by the user.
You must select a transfer switch that is the same size in amps (or larger) then your building service or sub-panel. The transfer switch must also be the same size in amps (or larger) than the maximum output of the generator you select. Example: If you have a 12 kW generator operating at 120 VAC single phase, (100 Amps) and a 200 amp building service you need a 200 Amp transfer switch or you must install a 100 Amp sub-panel. Transfer switches should be installed by a licensed electrician. For more information on transfer switches please see About Transfer Switches.
Select a transfer switch to go with your generator from the drop down option list on this page under Product Options. The transfer switches shown are compatible with this generator. If you need additional transfer switch poles, auxiliary contacts or communications features see ASCO Transfer Switches. For special needs, volume purchases and other questions, call your GeneratorJoe sales representative at 707 542-2224 for assistance. All ASCO switches are shipped FREE when you purchase the switch with a generator.
Other Requirements or Options and GSA: If you do not find the options you need in the drop down option windows above or if you have other requirements, please call us and tell us what you require. If your needed option is not available we have many other brands that may provide the options you need or we will have a generator custom made if necessary. Please contact us at (707) 542-2224 or write [email protected]. If you are a college or university, federal, state, county, city or government agency customer write to [email protected].
CLICK>Open Specification Window on the blue bar immediately above to see detailed specifications on this product. A window will fold down.In the opened specification window you can find conversions for metric measurements, single phase deration of three phase units, derating calculations for elevation and temperature as well as fuel consumption and total run time by tank size. Click the Open Specification Window button to see these utilities and additional information.Accessories available for this model are shown in Product Options above. Select an option in the drop down windows and the price will be recalculated automatically. Additional Information on this product is available on buttons and links at the bottom of this page. Transfer Switches shown on in Product Options (above) are matched to this generator. For details about transfer switches go to the Additional Information below. Please see our extensive educational area on the left side blue column of this screen under the Information sign.
Generator engine and alternator on welded steel frame, enclosed skid mount platform, rubber isolators, 7.4 gallon day tank, analog (guages) control panel,Standard, emergency stop switch, mechanical governor, residential muffler (enclosed models), industrial muffler (open models), 12 volt electric starter, included charging alternator, air filter, radiator, blower fan and guards, battery tray, battery cables, oil drain cock and extension, exhaust pipe weather cap, owners manual and warranty. Batteries are included. Other options are NOT included, please purchase the options from the option lists. Units are shipped on skids with shrink wrapped plastic film over entire unit. -
The packages shown below are the most common combinations of options. Each package includes only the options listed. Also see Included Equipment above.
If you want a Package deal but need additional options, select the options in the drop down windows above, then check the box "Option Only", Click the Product BUY button and then Click the "Package" BUY button next.
You can also select all the options you want and just click the product BUY button and select your custom configuration. -
Purchase option onlyGenerator engine and alternator on welded steel frame, enclosed skid mount platform, rubber isolators, 7.4 gallon day tank, analog (guages) control panel,Standard, emergency stop switch, mechanical governor, residential muffler (enclosed models), industrial muffler (open models), 12 volt electric starter, included charging alternator, air filter, radiator, blower fan and guards, battery tray, battery cables, oil drain cock and extension, exhaust pipe weather cap, owners manual and warranty. Batteries are included. Other options are NOT included, please purchase the options from the option lists. Units are shipped on skids with shrink wrapped plastic film over entire unit.
-
Standard FeaturesGL Series, 11 kW (11 kVA) 60 Hz, SKU KUPR-011D102, Model GL11000-USA, Portable Diesel GeneratorAnalog Control PanelGenerator and Engine are directly coupledLarge capacity fuel tank (7.4 US gal)EPA Tier 2One-side maintenance realizedDouble Circuit protectorAutomatic shutdown high temperature/oil pressureEquipped with a starter safety relayDouble element air cleanersAccess terminal to connect to the Automatic Transfer SwitchesOptions AvailableGL Series, 11 kW (11 kVA) 60 Hz, SKU KUPR-011D102, Model GL11000-USA, Portable Diesel GeneratorTwo Wheel kitRemote control kit
-
To get started with a lease, click the button below.
-
To see a list of generators in each category CLICK on these links.All Industrial, GeneratorJoe, Diesel, Single phase ~~~ All Industrial, GeneratorJoe, Diesel, Three phaseAll Industrial, GeneratorJoe, Gaseous, Single phase ~~~ All Industrial, GeneratorJoe, Gaseous, Three phase
-
To search for other products click the button below.
-
To find transfer switches click the button below.