ASCO Logo Series 7000 Service Entrance

%%SHORT%%
185 Manual or Automatic, Door Closed
 
Series 7000 Service Entrance, Industrial Automatic Transfer Switches, Transition, For Critical Applications
ASTR-7000S (1534)
150 to 4,000 Amp, Indoor, Outdoor, Explosion Proof, Stainless & Accessories. Standard, Delayed, Closed Transition, Soft Load, and Bypass Isolation configurations.100, 200, 230 & 400 Amp, Indoor & Outdoor, Light Duty,    >>>>Order online or call PowerPixie @ 707 542-2224 to take your order. GSA Pricing Available.
Ship Via
UPS Ground
List Price
You Save
Our Price
Request Info
Plus Options
Qty
Update Qty
  • Detailed Description

    ASCO Transfer Switch Group - Automatic Transfer Switches - Enclosed - Series 7000 - Service Entrance
    As the world leader in emergency and standby power transfer solutions, ASCO keeps your power on. ASCO, Automatic Transfer Switches and Power Systems safeguard data and telecommunications networks, industrial processes and critical installations from health care facilities to financial transaction centers.

    Over the past 70 years, ASCO has pioneered every major product innovation in power transfer technology. And ASCO is committed to providing a full range of quality-driven products, backed by 24-hour nationwide service support.

    ASCO Series 7000 Service Entrance - ASCO 7000 Service Entrance Series automatic transfer switches when critical power protection and a service entrance configuration is required.

    The ASCO Service Entrance Power Transfer Switch combines automatic power switching with a disconnect and over-current protective device on the utility source. The power transfer switch meets all National Electrical Code requirements for installation at a facility's main utility service entrance. Service entrance rated transfer switches generally are installed at facilities that have a single utility feed and a single emergency power source. A circuit breaker serves as the utility disconnect and links are provided to disconnected both neutral and ground connections.

    Standard, Delayed, Closed Transition, Soft Load, and Bypass Isolation configurations.

    • Standard models in stock dropped shipped to your location. We will assist you in configuring your switch. Factory engineering assistance is provided at no charge.
    • Available in NEMA Type 1, 3R, 4X and 12 enclosures up to 600 VAC and from 150 to 4000 amps.
    • Available in Standard, Delayed, Closed Transition, Soft Load, and Bypass Isolation configurations.
    • UL 1008 and 891 Listed automatic transfer equipment standards.
    • For technical data, dimensions, features, remote controls, monitoring, warranty, and other information. See Additional Information below.

    There are several types available within the 7000 Series, Service Entrance. Click on the link to go to that product.

    CALL FOR PRICING: Due to the extensive array of types, options and accessories please contact the GeneratorJoe sales department for competitive pricing.

    Call GeneratorJoe at 707 542-2224 or write [email protected].

    ASCO 7000 Series - Service Entrance - Transfer Switches - Product Features
    Seamlessly transfers loads between acceptable utility power and onsite generation with virtually no voltage or frequency transients   Transfers power using proven ASCO Closed-Transition Transfer Switches (CTTS)
    Automatically selects emergency standby transfer operation upon loss of utility power   Enables you to monitor and control Service Entrance operation using GUIs (graphical user interfaces) with user-friendly, pull-down menus
    Actively synchronizes the onsite generating unit to the utility source by automatically adjusting the generating unit's governor and voltage regulator (analog or pulse width modulated outputs control the governor)   Allows you to activate protective functions using the touch screen (each function can be programmed to signal an external breaker and/or alarm signal, or just display the condition on the GUI)
    Maximizes security with multiple levels of password protection   Contains protective functions on utility and generator sources required for ongoing parallel operation
    Records and time stamps events and all changes to protective function settings   Provides digital inputs with the adjustable trip and reset time delays to control or monitor external devices
    Conventional two-position transfer configuration, plus closed and delayed transition modes of operation. All configurations are available with either automatic or non-automatic control.   Independently qualified and certified listed to IEC 60947-6-1, CE marked (optional). (Limited to certain accessories.)
    UL listed to 891 and 1008 Transfer Switch Equipment & CSA certified to CSA 22.2 No. 178-1978 Automatic Transfer Switches.   High withstand and close-on ratings including 30 cycle withstand current rating for optimum flexibility in circuit breaker coordination
    Rated up to 600 VAC, 150 through 4000 amperes.   Reliable and field proved a solenoid operating mechanism.
    Solid, switched, or overlapping neutral conductor options.   Front replaceable main and arcing contacts (600-4000 amperes).
    Programmable microprocessor controller with keypad and LCD display.   Centrally located terminal block for customer control connections (260-4000 amperes).
    16mm, industrial grade control switches and indicating lights.   Four auxiliary contacts, two contacts closed when the switch is in normal position and two contacts closed when the switch is in emergency position.
    Local/remote serial communications capability (including the internet) for interfacing with ASCO SiteWebTM communication products.   Ten Year Warranty
     
  • This product does not have designated product packages.

    Please see the Priced Options tab and select the options you want supplied with the product. Prices will update automatically when you select or remove an option.

  •  
    Purchase option only
    Transfer Switch Voltages @ 60 Hertz Details
    Transfer Switch Voltages @ 50 Hertz Details
  • Standard Features
    Series 7000 Service Entrance, Industrial Automatic Transfer Switches, Transition, For Critical Applications
    Close differential 3 phase under-voltage sensing of Source1 (normal) - factory standard setting 90% pickup, 80% dropout (adjustable); under-frequency sensing of Source 1 factory setting 95% pickup (adjustable).
    Contact transfer speed less than 100 milliseconds
    eTemperature rise test per UL 1008 conducted after overload and endurance tests in unventilated enclosure-exceeds UL requirements
    High close-in and withstand capability
    NEMA Type 1 enclosure is standard. Also available in NEMA 3R, 4, 4X & 12.
    Voltage and frequency sensing of the Source 2 (emergency) - factory standard setting 90% pickup voltage, 95% pickup frequency (adjustable).
    Indicating LEDs for source availability and switch position.
    Pushbuttons for test, exerciser set, timer bypass and program cancel.
    Special status annunciation of in-phase transfer and timer operation.
    Selectable 7, 14, 21 or 28 day (factory set 28 dsays) generator (source2) with or without load exerciser timer.
    Diagnostic LED indications in logical one-line configuration.
    Auxiliary contacts (1 each) cclosed in Source 1 (normal) and Source 2 (emergency positions.
    Close differential under-voltage sensing of the normal source.
    Voltage and frequency sensing of the emergency source.
    Test switch (fast test/load/no load) to simulate normal source failure - automatically bypassed should the emergency source fail .
    Double throw, interlocked operation .
    Electrically operated, mechanically held by a simple, over-center mechanism.
    Segmented silver tungsten alloy contacts with separate arcing contacts on 600 amps and above.
    Arc quenching grids, enclosed arc chambers and wide contact air gap for superior source-to-source isolation on all units.
    Control circuit disconnect plug and drive inhibit switch for safe maintenance.
    Components accessible for inspection and maintenance without removal of the switch or the power conductors.
    Mechanical indicator and contact chamber cover designed for inspection, safety and position designation.